Sorvall · Model WX Ultra Series
Easy to Operate • Set RPM or RCF: No protocol conversion necessary • Real-time control: Sample ready when you are – set delayed start/stop • Program memory: Save time by storing up to 20 programs into memory along with User ID and comments • Color touch screen: Easy selection of run parameter and operation. For routine spins, simply enter speed, time and temperature parameters. Dual display of SET and RUN conditions allow you to verify performance at a glance. • Run scheduling: Reserve the centrifuge for a future day and time Outstanding Control with UltraSecur™ • User lockout feature prevents unauthorized access • Run scheduler allows you to schedule runs at your convenience • Rotor life management tracks rotor usage and alerts you when rotors need to be serviced or replaced Excellent Space Savings and Efficiency • Quiet Operation (53dBA): Eliminates noise distraction so you can place it in the lab where you work • Energy Saving: Less than 20 amp load reduces power consumption up to 15% over the competition and eliminates burden on HVAC systems • Better Ergonomics: 3” lower deck height for easier rotor loading/unloading; door opens with just a push. Smaller footprint utilizes less of your valuable lab space • Imbalance-Tolerant Drive: Saves time with visual tube balancing Easier Sample Loading for Safer Separations • Unique StepSaver™ rotors use cartridges to streamline sample loading and unloading steps, minimizing sample loss • SureSpin™ rotors prevent swinging buckets from being loaded improperly, avoiding sample loss, run shut-downs and rotor failures
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.