Sorvall · Model ST 16
• Ideal for everyday sample processing, including clinical protocols, cell culture applications, microplate processing and a variety of separation needs • ClickSeal® Bucket Sealing System - Simple glove-friendly, one-handed open/close capability eliminates screw caps and complicated clips Auto-Lock® III Rotor System - Installation and exchange of rotors with just the push of a button for quick switch between applications and time savings in the lab • Easy access to the chamber enables quick cleaning, a healthier working environment and longer unit life • Motorized Lid Latch - One finger downward motion for easiest closing and locking – even on tall benches • SMARTSpin® Management System - Optimal acceleration, braking and residual load imbalance for each rotor and bucket option resulting in smooth runs and reproducible results • Simple, Intuitive Controls - Detailed operation information to maximize run performance • Highly visible backlit display for clear reading of running parameters across the lab • Compact footprint for optimal work-space • Ergonomic height and curved design allow comfortable sample loading and unloading and easy cleaning
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →