Sorvall · Model RC-4
• Shorter processing times for more samples - The RC-4 is designed to spin larger numbers of tubes at higher RCFs. Its powerful induction drive and swinging bucket rotor - which accommodates DoubleSpin buckets - combine to provide higher ‘g’s and capacities for the most popular sample formats. • Spin more tubes at higher RCFs - The RC-4 offers exceptional capacity for all popular sample formats, including 15 and 50 ml tissue culture tubes, and many others. Spin even DNA and RNA filters plates under biocontainment at 5,890 x g! • High capacity processing for all labs - With its wide range of rotors, the RC-4 is equally at home in biochemistry, biotechnology, microbiology, pharmaceutical and blood processing labs. • Safe operation - The RC-4™ meets stringent international safety standards. It offers the widest selection of independently tested biocontainment rotors that comply with rigorous international guidelines for aerosol containment of bacteria and viruses. • Optimum run stability - The SMARTspin™ Imbalance Detection System will automatically brake the centrifuge if an excessive imbalance is detected, for example, due to tube leakage. Reliable imbalance detection means that even large swinging-bucket rotors can operate safely with a 30 gram imbalance. • Easy to use - Unlike other models, the EASYcontrol™ II Soft-Touch Keypad is located at the front of the instrument, eliminating awkward reaching. • Enhanced user safety - choose from 5 biocontainment rotors accommodating samples from 1.5 - 1,000 ml • Large 4 liter/8 blood bag capacity • Fastest processing and highest throughput of any 4 liter low speed centrifuge • Unmatched ‘g’s with fixed-angle rotors for bacterial, tissue culture and general pelleting needs • Accepts 32 standard microplates or 8 deepwell plates • HIGHplate® rotor spins DNA/RNA filter plates to 85 mm in height • Optimum run stability with SMARTspin™ Imbalance Detection System • Easy-to-clean soft-touch keypad • Reduced maintenance with brushless induction drive
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.