Sorvall · Model RC-12BP
• Quality Separations - The Sorvall RC12BP helps ensure high-quality separations through a variety of features, including the MSR™ System for minimum sample disturbance. • Increased Productivity - With the H-12000 rotor, you can process up to 12 blood bags with 500mL collection volume each. • Automatic Reproducibility - Simply choose the ACE button, enter the total Accumulated Centrifugal Effect™ for your protocol, and the centrifuge will automatically compensate for variations in acceleration times due to differences in a full or partial rotor load by adjusting the run time. • Customize runs for Maximum Yields - Control the rates of acceleration and deceleration with the MSR™ (Minimal Sample Resuspension) System. Using the Slow Start/Slow Stop features, you can choose from 10 acceleration and deceleration profiles, allowing you to customize runs for minimal sample resuspension, cleaner interfaces and maximized product yields. • Easy to Use - The Sorvall RC12BP centrifuge features easy-to-use, menu-driven controls – including a storage and recall function of up to 15 separation protocols – for fast and easy centrifuge processing.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.