Sorvall · Model Legend 23R
Maximum productivity • The Legend 23R excels in a wide range of applications including nucleic acid purification, PCR cleanup, plasmid mini-prep, protein processing and forensics. • Its flexibility with its extensive rotor library (12 rotors) extends the capabilities of this unit. Ideal for shared labs. • Auto-lock feature allows for easy rotor exchange. Ideal for users who convert between microplate and microtube rotors. Provides significant time savings that increases productivity - so you can accomplish much more in less time. High Performance Refrigeration System • Ensures samples are kept at 4C even when unit is run at maximum speed. This precise temperature control ensures no sample degradation and better quality of separation leading to improved results. • Exceptionally quiet with a 57dBA, so you can conduct your research all day long without distraction. • Excellent Value - The addition of the FiberLite 48 place rotor provides the Legend 23R with the competitive edge – higher capacity and performance ability, allowing you to spin more tubes at a faster rate- resulting in savings of time and money. • Protection and Assurance - CAMR- approved biocontained accessories Protection and assurance for users that spin toxic or infectious materials desiring aerosol containment.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →