Sorvall · Model Legend 14 Personal Mic
Easy to use • Rotors and tubes are inserted and removed with minimal effort • A large LED display simplifies viewing of parameters and eliminates any confusion • Setting parameters is also fast and simple using a single knob - no need to bother with toggling arrow keys or imprecise analog controls • A snap to clean: its plastic rotor is fully autoclavable and non-corroding, and the unit features a brushless motor that offers years of maintenance-free operation. Maximum productivity • Operating at 14,500 x g, it can hold 12 micro tubes from 0.5 to 2.0 mL and supports smaller volumes with adapters • Excels in a wide range of applications including nucleic acid purification, PCR cleanup, plasmid mini-prep, protein processing and forensics • Its fast spin up/spin down offers significant time savings that increases productivity - so you can accomplish much more in less time Compact and quiet • 76.5 square-inch footprint (delivers consistent results without taking center stage on your bench-top) • Exceptionally quiet so you can conduct your research all day long without distraction
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →