Sorvall · Model HT-6
• High throughput Processing: high capacity processing includes 216 x 5/7 mL blood tubes, most popular clinical racks, RIA tubes, 42 standard microplates, 18 deepwell plates, and 42 x 50 mL conicals all in sealed buckets • Application Flexibility: can process blood and/or tissue culture tubes, popular clinical racks, microplates, RIA tubes, and flasks/bottles up to 1L • Intuitive VIDEOset interface: provides an easy-to-read screen with online help and powerful programming features • CQCS Traceability Software: Provides sample and unit traceability for convenient compliance with GLP/GMP standards (computer control) • Small Foot Print: for its high capacity processing • Workhorse Performance: Robust, maintenance- free brushless motor, windshield rotor • Applicability in Multiple User Environment: 24 program memory, and intuitive interface to accommodate multiple user protocols
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →