Sorvall · Model Evolution RC
Fastest, easiest processing in the industry With the F8S-6x100Y SUPER-LITE composite rotor, users will process 6 liters of sample in a single run. Combining speeds to 26,000 rpm with faster accel/decel times than competitive centrifuges, the Evolution RC reduces overall spin times and optimizes productivity. Rotors and Accessories Sorvall's complete line of rotors, tubes and bottles will meet all application needs. With the addition of the newly designed 1L bottle, offers users the complete system – centrifuge, rotor and bottles all in one. Consistent performance, longer life The built-in Constant Power System (CPS) provides power factor correction to ensure peak performance even under poor power supply conditions. Input voltage can vary from 187 – 253 V without speed or temperature control degradation. Easily accessible, hands-free rotor access The Evolution RC’s deck is only 850 mm (33 inches) from the ground – the lowest profile on the market – which makes the rotor chamber and control panel easily accessible.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →