Sorvall · Model Discovery 100SE
• Maximum speed of 100,000rpm (802,006 x g) • Simple keypad and large LCD display for easy set-up of routine spins . Control panel is simple with easy key operation and easy-to-see liquid crystal screen. • The displayed language can be switched over between English and Japanese • The real-time control (RTC) feature enables setting a start time or a finish time, thus letting you run your machine at a desired date and time. • Centrifugal force (RCFmax and RCFavg) can be displayed and set. • Twenty varieties of nine stepped modes can be programmed for a wide range of applications. • Various alarms notify users of causes and necessary actions when fault conditions are detected allowing easier and quicker troubleshooting. • Low noise level makes the ultracentrifuge suitable for use in any laboratory. • Samples can be easily balanced visually. • CFC-free thermoelectric cooling system with greater cooling capacity.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →