SKYTRON LLC · Model I5-PT
I5 Washer Disinfector w/ dual automated doors 35.5"W x 33"D x 79"H, hot, cold and fil rinse water connection, 2 chemical pumps, integrated dryer, drain cool down, 4 level rack, Steam, 208V
Intended use: An electrically-powered unit intended to be used for both chemical and thermal disinfection of probes, surgical instruments, and/or endoscopes, and their accessories. It may include washing features and may have built-in features to circulate cleaning and disinfectant solutions through a device lumen; some types may also have built-in drying features. It is not intended for device sterilization.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pressure loss, long cycle, steam leak.
Root cause: Aged rubber gasket.
Symptoms: No steam, low temp, cycle abort.
Root cause: Failed heating element or scale buildup.
Symptoms: Poor air removal, non-condensable gas fault.
Root cause: Worn vanes/seals.
Symptoms: Temp out of tolerance, failed Bowie-Dick.
Root cause: Sensor aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
Most-replaced wear item.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Chamber temperature sensor | Periodic replacement | $$ | Moderate |
| RO/DI feed cartridge Consumable. | Frequent wear item | $ | Easy |
| Door gasket / seal Most-replaced wear item. | Periodic replacement | $$ | Fairly easy |
| Steam generator heating element | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →