Siemens Healthineers · Model Luminos Agile
The first patient-side system with true dual-use capability for fluoroscopy and radiography • Improve the patient’s experience, customer satisfaction, and your competitive advantage • Cater to a broader spectrum of patients more successfully • Optimal radiography with the Ysio option increases utilization rates The first patient-side system with a flat detector for fluoroscopy and radiography • High-quality dynamic and static imaging with the 43x43 cm (17“x17“) flat detector • Comprehensive dose reduction with CARE • Unlimited imaging flexibility with the Ysio option The first patient-side system with a height-adjustable table for fluoroscopy and radiography • Adjustable table from 65 to 112 cm (25-44“) height for easy patient transfer • Effortless system movement with the fully motorized tower • Open design and high weight capacity up to 275 kg (606 lbs) to cater to all patients more easily
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →