Siemens Healthineers · Model CA 620/660
Automated probe rinse eliminates manual steps Simultaneous analysis of results frees up time Increase D-Dimer throughput by 40? Hand-held two-dimensional barcode reader simplifies the data entry process for ISI, control and calibrator values, lot numbers, and expiry information Sample barcode reader provides simplified sample ID processing and enables security and integrity of patient records 25% less power consumption Minimal consumables needed - only CA Clean I, CA Clean II, and reaction tubes Only one reaction tube used per test Results correlate with the entire line of Siemens hemostasis systems Provides confidence through standardized results Hand-held 2-D bar-code reader automates the data entry process for calibrator and control values Easy-to-use system handling with intuitive menu structure and tilted color touchscreen STAT sample processing enables critical tests to be processed at any time Analyzed data may be displayed or printed with reaction curves for flexibility in result management Environmentally friendly system with minimized reaction tube waste Menu includes the most frequently requested routine and specialty tests, including INNOVANCE D-Dimer
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →