Siemens Healthineers · Model CA 620/660
Automated probe rinse eliminates manual steps Simultaneous analysis of results frees up time Increase D-Dimer throughput by 40? Hand-held two-dimensional barcode reader simplifies the data entry process for ISI, control and calibrator values, lot numbers, and expiry information Sample barcode reader provides simplified sample ID processing and enables security and integrity of patient records 25% less power consumption Minimal consumables needed - only CA Clean I, CA Clean II, and reaction tubes Only one reaction tube used per test Results correlate with the entire line of Siemens hemostasis systems Provides confidence through standardized results Hand-held 2-D bar-code reader automates the data entry process for calibrator and control values Easy-to-use system handling with intuitive menu structure and tilted color touchscreen STAT sample processing enables critical tests to be processed at any time Analyzed data may be displayed or printed with reaction curves for flexibility in result management Environmentally friendly system with minimized reaction tube waste Menu includes the most frequently requested routine and specialty tests, including INNOVANCE D-Dimer.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Flagged or implausible CBC counts, voteouts, clog alarms, poor precision.
Root cause: Debris or a clot partially blocking a counting aperture or the flow cell.
Symptoms: Short samples, aspiration errors, cap-piercing failures, carryover.
Root cause: Worn or bent sample probe / closed-vial piercer, or a worn shear / segment valve.
Symptoms: WBC, HGB or diff results shifted, high background, reagent alarms.
Root cause: Reagent depleted or wrong lot, or a pinch-valve / tubing fault.
Symptoms: Diff scattergrams abnormal, missing populations, flow-cell or laser alarm.
Root cause: Contaminated or aged flow cell, or the laser / optics.
Symptoms: Multiple parameter errors, priming failures.
Root cause: Pump or regulator drift.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample probe / closed-vial piercer | Periodic replacement | $$ | Moderate |
| Shear / segment valve | Periodic replacement | $$$ | Difficult |
| Pinch-valve / peristaltic tubing | Frequent wear item | $ | Moderate |
| Flow cell | Periodic replacement | $$$ | Difficult |
| System reagents / controls | Consumable | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.