SeQual · Model Integra
Easy-to-read LCD flow indicator. The new flat panel cleans with a quick wipe. Alerts you if the O2 hose becomes restricted. Delivers up to 10 LPM of continuous O2 with the security and convenience only a concentrator can provide. Single, easy-to-clean cabinet intake filter is highly visible and easy to reach and remove for periodic cleaning. Compact cabinet with integrated handle and four swivel casters make movement easy. Hour meter can be easily accessed and viewed by service technician. Essentially the same size, weight, and power consumption as a 5 LPM machine. Internal 9 volt battery, with provider accessible reserve gauge, powers alarm if electric service is interrupted.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Oxygen-concentration alarm, delivered O2 below spec at flow.
Root cause: Aged sieve beds (molecular sieve), a compressor / valve fault, an air leak, or an inlet-filter blockage.
Symptoms: Weak or no flow, compressor noisy or hot, thermal cut-out.
Root cause: Worn compressor / valve heads, or a cooling-fan fault.
Symptoms: Flow will not adjust or does not match the setting.
Root cause: Worn flow-control valve or flowmeter.
Symptoms: Reduced performance, compressor working hard.
Root cause: Dirty gross-particle / cabinet / final bacteria filter.
Symptoms: Loud operation, rattling.
Root cause: Worn compressor mounts or a loose panel.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Molecular sieve beds | Periodic replacement | $$$ | Difficult |
| Compressor / valve-head rebuild kit | Periodic replacement | $$$ | Difficult |
| Inlet / cabinet / final filters | Frequent wear item | $ | Easy |
| Flow-control valve / flowmeter | Major service part | $$ | Moderate |
| Cooling fan | Periodic replacement | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
Extracted directly from this unit's own service manual.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.