Scilogex · Model SCI636
FREE rotor of your choice with purchase Suitable for tubes with caps, blood collection or urine tubes Speed can be set from 300 - 6000rpm Automatic rotor detection CPU controls all operating parameters including speed and time RPM or G-force are simply set and displayed Operation can be timed from 30 seconds to 99 minutes for short run/ continuous run Timer commences once the set speed is reached, so the separation time is more accurate 9 Acceleration / 10 Brake speed settings to ensure optimal separation Parameters can be modified after the set speed is reached Quick spins are possible by pressing and holding PULSE key Interlock automatic door lock 9 procedures stored in memory makes the operation much simplified Easy-to-read backlit LCD processing display and sound alert A wide range of accessories available (fixed angle and swing-out bucket rotors) cTUVus approved for UL and CSA Maintenance-free brushless DC motors drive quickly and effortlessly accelerates the rotor to set speed
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →