Scilogex · Model SCI24H
Precise control of speed and time separately, excellent performance Dual lid lock prevents opening during useCPU controls all operating parameters including speed and time RPM or G-force can be set and displayed Operation can be timed from 30 seconds to 99 minutes or continuous running Timer commences once the set speed is reached, so the separation time is more accurate Gentle braking at low speeds with efficient separation Parameters can be modified after the set speed is reached Quick spins are possible by pressing and holding PULSE key Automatic release the lid when operation has stopped to save processing time Easy-to-read backlit LCD processing display and sound alert Can be pulse accelerated and held at speed High strength aluminum hematocrit rotor included (optional fixed angle rotor for 1.5/2.0ml tubes) Comes with Hematocrit rotor for 24 x 1mm x 75mm capillary tubes Brushless motor drive quickly and effortlessly accelerates the rotor to set speed Optional micro-tube rotor: 1.5/2mL×24 max. speed: 14000rpm
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.