Scilogex · Model SCI124R
Large LCD display provides all visual information Bio-safe aluminum rotor/anti-sample overflow prevents accidental leakage during centrifugal process allowing risk-free microbial contamination Comes with a 24 place rotor, 1.5/2.0mL tubes. Optional adapters for 0.2mL and 0.5mL tubes Pre-cooling to desired temperature ensures optimal protection of the sample before warming Guaranteed 2°C cooling within only 7 minutes of both chamber and samples even at maximum speed and capacity utilization Sound-alert allows your undivided attention on other tasks warming Quiet running, noise level ≤ 54dB Lid lock facility allows for internal temperature maintenance even after centrifugation Intermittent temperature control mode, CFC-free refrigerant and low carbon life rotor capacity Brushless motor drive, maintenance free High quality aluminum alloy bio-containment rotors, safe and autoclavable for unlimited service life Special double cooling air design, reduces rotor heating -20°C to 40°C temperature range Powerful compressor and cooling system, fast cooling Optional rotors below include a 4 x 8-tube PCR strip rotor Pulse operation for quick spins Interlock automatic door lock Over-speed detection Over-temperature detector cTUVus approved for UL and CSA
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →