Schiller · Model CARDIOVIT AT-102
Resting ECG. Integrated 3-channel monitor. Alphanumeric keyboard. Direct keys for the most important functions. Easy Print: Integrated high-resolution A4 thermal printer, subsequent print-out on thermoreactive paper possible. Interface for external printer for A4 printouts on regular paper. Internal memory for up to 40 records. Interface for data-transmission Exercise ECG. RS-232 port for peripheral devices such as treadmills, bicycles etc. For exercise ECG, several standard protocols are available for bicycle and treadmill ergometers; the user can either select a standard protocol from a table or define a new protocol. J-point settings: J+20, +40, +60, +80 ms; default: +60 ms. Blood pressure (Blood pressure measurement: Automatic if a bicycle contains an interface for the blood pressure transfer or manual). 10-sec. printout: A 10-sec. printout can be initiated at any time on the internal thermal printer Spirometry. Unique disposable sensor SP-250 minimizes the risk of contamination. SP-260 with reusable sensor. Simple and fast calibration. Memory for up to 40 records. Inspiratory and exspiratory tests; pre and post medication tests - Selectable predicted value tables - Real-time curves and measurement information on the large screen.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Baseline wander, muscle or AC noise, "lead fail", poor 12-lead quality.
Root cause: Poor skin prep, dried or lifting electrodes, or a worn patient cable / lead set.
Symptoms: Acquisition hangs, no interpretation, or a self-test failure.
Root cause: Acquisition-module fault or a software issue.
Symptoms: No or faint report, paper jam, misregistered grid.
Root cause: Thermal print head, paper handling, or (older units) the stylus.
Symptoms: Short battery run time, will not hold charge, will not power on.
Root cause: Aged battery pack.
Symptoms: ECGs will not transmit to the ECG-management system / EMR.
Root cause: Network / Wi-Fi / modem configuration or the communication module.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable / 10-lead set | Frequent wear item | $$ | Easy |
| Acquisition module | Major service part | $$$ | Moderate |
| Thermal print head / paper | Periodic replacement | $ | Fairly easy |
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Communication / modem module | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
From BioLab, for work done with this kind of equipment.