HP · Model PageWriter 200i
• Simultaneous acquisition of up to 12 leads • Real-time, continuous recording of 3, 6, or 12 channels • Recording speeds of 5, 10, 25, or 50 mm/sec. for capturing multiple levels of detail • Extensive ECG quality control features include AC noise filtering and baseline wander correction • ACI-TIPI helps predict the probability of acute cardiac ischemia • TPI helps identify patients having acute myocardial infarction (AMI) who might benefit from thrombolytic therapy • Automatic interpretation of ECG data using clinically proven algorithm • Adult and pediatric analysis programs standard • Full-page English (A size) or metric (A4 size) reports for convenient reading and filming • Color-coded operation keys make learning almost intuitive • Dedicated function keys (ID, Filter, Copy, Speed, etc.) for frequency used operations • Easy-loading allows fast, hassle free paper replacement
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.