RTI Group North America · Model Cobia Dental
li.li1 {margin: 0.0px 0.0px 0.0px 0.0px; font: 12.0px Carlito; color: #191c1f} span.s1 {font: 10.0px Symbol} span.s2 {background-color: #ffffff} ul.ul1 {list-style-type: disc} Easy to position with no position dependence Large, rotatable display Log/History function "Plug n Play" function Pulsed radiation analysis Full Auto range for kV, TF, and Sensitivity Bluetooth and USB communication Solid-state detectors = no need to compensate for temperature & pressure Built-in energy compensation Long-lasting rechargeable battery Always free firmware upgrades Up to ten-year warranty Two-year Calibration Cycle
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Readings out of tolerance on verification check.
Root cause: Reference component aging.
Symptoms: Won't power on, unexpected shutdown mid-test.
Root cause: Aged internal battery or PSU.
Symptoms: Intermittent or no reading through a specific lead.
Root cause: Repeated connect/disconnect cycles.
Symptoms: Blank, frozen, or garbled display.
Root cause: Display module or driver board aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep spares.
Send out for annual re-certification.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test lead set High-turnover; keep spares. | Periodic replacement | $$ | Easy |
| Display module | Major service part | $$$ | Difficult |
| Calibration reference module Send out for annual re-certification. | Major service part | $$$$ | Difficult |
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Incorrect instructions for use (IFU) included.
RTI Surgical, Inc. of Alachua, FL is recalling their OPTEFORM Allograft Paste, 5cc as it may contain a 10 cc fluid dispenser. The 10cc fluid dispenser does not include the correct fluid fill line reference for reconstitution of 5cc past allografts.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →