Roche · Model URISYS 1800
Easy to Operate User-friendly operation - simply dip and insert the urine test strip Save time with automatic transmission of results to Host PC after each measurement Flexible entry of sample ID with barcode scanner or alpha-numeric keypad Complete test parameter menu Specific Gravity, Leukocytes, Bilirubin, Urobilinogen, Glucose, Ketones, Protein, pH, Blood, Nitrites, and Urine Color via test strip. Risk-free color interpretation Ensure consistency of results with automatic color measurement Programmable setup options include 8 color determinations Reduce false negative results and the need to retest Virtually eliminate Vitamin C interference for blood and glucose CHEMSTRIP technology consistently measures both acetoacidic acid and acetone Attractive Software Features Touch screen display with clearly arranged software functions Positive sample identification via barcode scanner Result memory for 1000 samples and 300 control samples Various flagging options for sample and control results Bi-directional serial interface for host communication Easy system calibration using special calibration strips Minimal operator time for calibration and maintenance Calibration required only once every 4 weeks Daily maintenance takes less than 1 minute
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.