Rigel Medical · Model VenTest 800
All-in-one analyzer - The all-in-one adult, pediatric and high-frequency ventilation measuring modes make the VenTest the ideal calibration tool for all ventilators, anesthesia machines and spirometers. Measures and calculates all common respiratory parameters - Flow, volume, pressure, oxygen, temperature, humidity (measured) and Vti, Vte, Vi, Ve, Ti, Te, Ti/Ttotal, Ppeak, Pmean, I: E, PEEP, Rate, PF Insp., PF Exp., Cstat, Pplateau and Delta P (calculated). Compatible with gas standards and gas types - Built-in compatibility for measuring ventilator performance in 13 gas standards and 10 gas types such as: Air, O2, N2O, He, N2, CO2 and Mixed: Air/O2, N2O/O2, He/O2. Built-in data storage with optional software for total traceability -. The VenTest has an internal memory that allows you to store up to 10 records, each containing up to 16 measurement values, eliminating the risk of manual data capture error and the hassle of paperwork. USB, RS-232 and external trigger interface - The VenTest communicates with your test software and ventilator to improve automation, increase traceability and standardize the process of testing ventilators. Portable with battery operation - Up to 3 hours of battery life provides convenient and fast testing when you are on the go or without access to mains power Ventilator Analysis Test Functions. Bidirectional flow. High and low pressure. Differential and barometric pressure. Oxygen concentration. Temperature. Dew point. 7 anesthetic gas concentrations (with OR703). Respiratory parameters.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Readings disagree with a reference standard, verification check outside tolerance.
Root cause: Normal drift - the instrument needs its scheduled factory / accredited calibration (at least every 12 months).
Symptoms: Dead unit, short battery life, will not charge.
Root cause: Depleted or aged battery, or a power / charger fault.
Symptoms: Open or intermittent readings, connection errors, a specific function fails.
Root cause: Worn or broken test leads, mains adapters, patient-lead adapters, or a sensor cable.
Symptoms: One parameter (leakage, insulation, ECG / SpO2 / IBP simulation, defib / pacer energy, ventilator flow / pressure, light / dose) errors or is out of range while others work.
Root cause: An internal source / measurement circuit fault on that channel.
Symptoms: The automation / logging software will not connect.
Root cause: USB cable / port or driver.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
At least every 12 months per the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test-lead / adapter set | Periodic replacement | $$ | Easy |
| Battery | Periodic replacement | $$ | Easy |
| Calibration (factory / accredited) At least every 12 months per the manufacturer. | Frequent wear item | $$ | Easy |
| Communication cable | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
From BioLab, for work done with this kind of equipment.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio