RaySafe · Model X2 Solo
All you need for you modalities. RaySafe X2 Solo is a new product line from RaySafe that covers the measurement needs of your specific X-ray modalities. It’s based on the same technology as RaySafe X2, highly esteemed for its user-friendliness and performance, but instead of multi-modality capability, each model meets specific needs. Within your X-ray modalities the X2 Solo will meet all your QA or service measurement needs. RaySafe X2 Solo users will enjoy a large touch screen showing all parameters simultaneously, sensors ready for measurements without special settings or modes and a base unit storing all readings and showing full waveforms. Plus, much more. It’s true ease-of-use, which saves valuable time and minimizes the risk of making faulty measurements.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Readings out of tolerance on verification check.
Root cause: Reference component aging.
Symptoms: Won't power on, unexpected shutdown mid-test.
Root cause: Aged internal battery or PSU.
Symptoms: Intermittent or no reading through a specific lead.
Root cause: Repeated connect/disconnect cycles.
Symptoms: Blank, frozen, or garbled display.
Root cause: Display module or driver board aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep spares.
Send out for annual re-certification.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test lead set High-turnover; keep spares. | Periodic replacement | $$ | Easy |
| Display module | Major service part | $$$ | Difficult |
| Calibration reference module Send out for annual re-certification. | Major service part | $$$$ | Difficult |
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.