Quanta System · Model Thulium Fiber Laser
Lithotripsy First in vitro and in vivo experiences suggest strong potential for TFL technology in stone ablation. The peak power of TFL enables extremely limited retropulsion, while providing gentle stone dusting and generation of tiny particles. Indeed, TFL technology proved so far as an excellent dusting tool, in particular for low-medium hardness calculi. The wide frequency range (up to 2500 Hz) allows to speed up the treatment once you found the desired pulse energy and pulse duration combination. Fiber Dust further allows full performances already with 200µm core fiber, leaving space for output increase when needed. Additionally, the 150µm fiber allows even greater flexibility and irrigation flow. BPH & Soft Tissue Surgery Thulium wavelength is strongly absorbed by water, allowing efficient and precise ablation and incision of soft tissues. A maximum output power of 60W enables low-power. In particular, with Fiber Dust you can choose between a superpulsed ThuLEP (with higher peak power) and a more traditional continuous emission ThuLEP. Because of its features, Thulium laser can also be used for smooth ablation, resection and incision of urinary soft tissues requiring low-medium power, such as for the treatment of bladder and ureteral tumors, and urethral stricture.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Weak or no output at the delivery device, treatment ineffective, power not reaching the set value.
Root cause: Laser module / lamp / diode-bar ageing, a damaged delivery fibre / handpiece / applicator, or a driver / power-supply fault.
Symptoms: Unit shuts down after a period, over-temperature or low-flow alarm.
Root cause: Chiller / TEC fault, low or contaminated coolant, a failed pump, or blocked airflow.
Symptoms: Burn marks at the tip, high loss, intermittent output, applicator not recognised.
Root cause: Damaged or contaminated fibre / applicator / connector.
Symptoms: Skin cooling not delivered, cooling / cryogen alarm.
Root cause: Contact-cooling / cryogen supply, a valve, or the tip.
Symptoms: Laser will not fire, key / interlock / footswitch error.
Root cause: Footswitch, door interlock, or key-switch fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Power re-calibration required after replacement.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Laser module / lamp / diode bar Power re-calibration required after replacement. | Periodic replacement | $$$$ | Expert-level |
| Delivery fibre / handpiece / applicator | Frequent wear item | $$$ | Fairly easy |
| Chiller / TEC components & coolant filter | Periodic replacement | $$$ | Difficult |
| Contact-cooling tip / cryogen valve (aesthetic) | Periodic replacement | $$ | Moderate |
| Footswitch | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.