Pronk Technologies · Model SC-5 Simcube + OxSim Flex kit
NIBP Simulations Adult (120/80 mmHg), Neonatal (70/40 mmHg), Hypertensive (190/120 mmHg), and Hypotensive (80/40 mmHg) NIBP Simulations Digital Manometer Over Pressure (Peak Detect) Test mode measures the peak pressure produced by the patient monitor. The readout latches the highest pressure valve sensed, in 0.1 mmHg steps Leak Rate Test Mode ECG/Respiration Simulations 12-lead ECG Simulation Arrhythmia Respiration Heart Rate/Respiration sequence Pacer IBP Simulations Invasive Blood Pressure (IBP) Dynamic values (120/80, 70/40, 190/120) 7 static IBP vualues (0, 25, 50, 100, 150, 200, 250) SpO2 Simulations Saturations in 1% increments (10-100%) Pulse rates in 1 BPM increments (25-240) Create custom preset simulations for faster Alarm Testing Perfusion Index levels in 1% increments (10-100%) Factory Preset Simulations: Saturation: 85%, Heart Rate: 80 bpm, Perfusion Index: approx. 2.0 Saturation: 95%, Heart Rate: 40 bpm, Perfusion Index: approx. 2.0 Saturation: 98%, Heart Rate: 80 bpm, Perfusion Index: approx. 2.0 Saturation: 98%, Heart Rate: 140 bpm, Perfusion Index: approx. 2.0 Saturation: 99%, Heart Rate: 80 bpm, Perfusion Index: approx. 2.0 Masimo rainbow SET® Compatible Automatic detection of SpO2 Manufacturer
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Readings out of tolerance on verification check.
Root cause: Reference component aging.
Symptoms: Won't power on, unexpected shutdown mid-test.
Root cause: Aged internal battery or PSU.
Symptoms: Intermittent or no reading through a specific lead.
Root cause: Repeated connect/disconnect cycles.
Symptoms: Blank, frozen, or garbled display.
Root cause: Display module or driver board aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep spares.
Send out for annual re-certification.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Test lead set High-turnover; keep spares. | Periodic replacement | $$ | Easy |
| Display module | Major service part | $$$ | Difficult |
| Calibration reference module Send out for annual re-certification. | Major service part | $$$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.