Pronk Technologies · Model Pressure MAX
Smallest biomedical Digital Pressure Meter on the market! Half the size of other pressure meters Extreme Performance - 2X More Accurate**: Narrow Port -300 to 400 mmHg. **Positive Pressure: ±0.2% of Reading or 0.3 mmHg, whichever is greater. Negative Pressure: ±1% of Reading Wide Port -14 to 100 PSI. ±1% of Reading or 0.05 PSI, whichever is greater Differential Port ±1% of Reading Pressure Testing of Fluid, Gas or Air (2 independent channels) User-selectable 11 units of measure to meet any application: mmHg, PSI, inH2O, cmH2O, kPa, atm, inHg, bar(a), bar(g), mbar(a), mbar(g) Thumbscrew Exhaust Port: expels air bubbles or fluids during testing (wide port) Set your own Pressure Targets and Pass/Fail Tolerance: confirm pressure results are in tolerance without reading the display. Unit glows to indicate tolerance: Blue (below tolerance), Green (within tolerance), and Red (over tolerance) Peak Pressure Indicator Digital Timer: start-stop integrated timer for leak / inflation rates Integrated Pronk Mobilize Wireless Solution provides automated testing and data collection capabilities. Runs on 2 AA batteries 4-year warranty Most rugged digital pressure / vacuum meter – passes drop testing 50 times from 3 feet.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Readings disagree with a reference standard, verification check outside tolerance.
Root cause: Normal drift - the instrument needs its scheduled factory / accredited calibration (at least every 12 months).
Symptoms: Dead unit, short battery life, will not charge.
Root cause: Depleted or aged battery, or a power / charger fault.
Symptoms: Open or intermittent readings, connection errors, a specific function fails.
Root cause: Worn or broken test leads, mains adapters, patient-lead adapters, or a sensor cable.
Symptoms: One parameter (leakage, insulation, ECG / SpO2 / IBP simulation, defib / pacer energy, ventilator flow / pressure, light / dose) errors or is out of range while others work.
Root cause: An internal source / measurement circuit fault on that channel.
Symptoms: The automation / logging software will not connect.
Root cause: USB cable / port or driver.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
At least every 12 months per the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test-lead / adapter set | Periodic replacement | $$ | Easy |
| Battery | Periodic replacement | $$ | Easy |
| Calibration (factory / accredited) At least every 12 months per the manufacturer. | Frequent wear item | $$ | Easy |
| Communication cable | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.