Philips Healthcare · Model ST80i
• Wireless, compact patient module reduces the hazard of tripping and enhances patient comfort and movement while still transmitting a clear, high-quality signal • Reduces motion interference with the elimination of unwieldy cables • Facilitates patient transition from exercise to bed for stress-echo procedure • Philips DXL Algorithm* uses sophisticated analytical methods for interpreting the resting ECG and ST Maps, the same algorithm used in Philips ECG equipment. • Philips CAlg algorithm is designed specifically for stress testing • View comprehensive ST segment and morphology analysis in an anatomically intelligent format. • View ST Maps, patented visual anatomical representation of ST deviations in frontal and horizontal planes • Quickly identify anomalies with the dynamic Zoomed ST display • Monitor ST changes with auto-comparison of current and reference beat • Watch for ST level and slope changes using the 12-lead average complexes • Clearly see arrhythmias with Dominant Rhythm Change notifications • Access comprehensive and customizable reports with prognostic indicators
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No pleth, SpO2 drops to --- or false low.
Root cause: LED/photodiode aging or cable damage.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Display / touch assembly | Periodic replacement | $$$ | Difficult |
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.