Philips Healthcare · Model BV Endura
Flexible choice between 9” or 12” image intensified Extended rotation for vascular projections SmartVision imaging technology Ultra-compact MobileView Station 1K2 imaging – a fully digital imaging chain with advanced noise reduction and 2D edge enhancements for higher image quality BodySmart – software that finds, tracks and defines the field of view to anatomy for ‘first shot right’ imaging Automatic Shutter Positioning – optimal shutter positioning for the best quality image possible and a clear view of the region of interest Automatic contrast/brightness – real-time contrast and brightness control at the touch of a button improves ease-of-use and provides faster control for better image quality
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Power supply unit | Major service part | $$ | Moderate |
| Network interface card | Major service part | $ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →