Philips Healthcare · Model Brilliance 64
A 64-slice CT scanner with Essence technology that delivers value, dependability, and performance. The Philips Brilliance CT 64-slice is one of the most advanced CT systems in the market. This system can expand clinical boundaries in cardiac, pulmonary, trauma, and pediatric imaging. This system is built on innovative Essence technology that delivers image quality, dose efficiency and rapid reconstruction times. The Brilliance CT 64 channel configuration package embodies completely the philosophies of sense and simplicity applied to more effective patient care. With a range of new and targeted advancements, including low-dose cardiac imaging, 3D volume software and expanded portal capabilities, this system takes the raw capabilities of volume imaging and makes them work harder for patients by making the physician’s work easier. This is the system for those who want the latest CT can offer, and realize productivity is an integral component of results.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →