
OxyHealth · Model Solace 210
4 psi portable mild hyperbaric chamber44 oz urethane. Designed for improved airflow through chamber. Rigid frame maintains form when deflated. Tamper-proof redundant pressure regulators. Medical Pass-throughfacilitates external device hookup. Clean air compressordouble head, oil-less, dual intake filters. High efficiency in-line filtration systemfilters to 0.01 microns. Bolster setcradles and stabilizes chamber when inflated. Custom mattresscontoured to fit inside the chamber. Chamber carry bag.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Chamber will not reach treatment pressure, or pressure bleeds off; long compression time.
Root cause: Compressor / air-supply fault, a door / hatch seal leak, a relief-valve fault, or a control-valve fault.
Symptoms: Delivered O2 low, O2-supply alarm, mask / hood not delivering.
Root cause: O2 supply / regulator, the delivery valve, or (concentrator-fed units) the concentrator.
Symptoms: Chamber too hot / cold or humid, patient discomfort alarms.
Root cause: Chamber A/C or ventilation fault.
Symptoms: No intercom to the patient, monitoring parameters missing.
Root cause: Intercom or the pass-through monitoring connections.
Symptoms: Crazing in the acrylic, worn door seal, fogging.
Root cause: Acrylic ageing (has a service life) or a worn seal.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Door / hatch seal | Periodic replacement | $$ | Fairly easy |
| Compressor / air-supply components | Major service part | $$$ | Difficult |
| Relief / control valves | Periodic replacement | $$ | Moderate |
| O2 regulator / delivery valve | Periodic replacement | $$ | Moderate |
| Acrylic hull / viewport (service-life item) | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.