Norav Medical · Model 1200HR
High resolution 12 lead ECG processing permits ST measurements and ischemia/Arrhythmia detection. Full disclosure EKG of entire test. 16,000 Samples/sec maximum (1200HR). Scroll back during the test to review episodes which may have been overseen. (S2). Heart Rate Recovery. Remote view on local network (S2). Export Formats- HL7, XML, JPEG, GDT, PDF (S2), DICOM. On-line filtering and automated baseline correction for stable ECG tracing. ECG screen display provide exceptionally clear tracing for visual view and on screen measurement. Plain paper ECG strips during test at user requests (Thermal printer is available). Acquisition, display and analysis of all 12 leads. Display and print out of ST levels and slopes. Remote view is possible. User defined J point. Controllable during study. Retrospective J point and isoelectric placement (on stored study). User initiated and automatic capture of events. Blood Pressure entrance and display of trend. Heart Rate achieved / expected display and trend. Display of 12 beats average or enlarged single beat. Save full disclosure study on disk for post processing. Standard Stress Test protocols: Bruce, Balke, Ellestad, Kattus and USAFSAM. Unlimited user programmable protocols. Automatic control of treadmill ergometers and blood pressure. Compatible with SunTech Tango+ blood pressure monitor. Oxygen uptake and METS estimation. Super imposition display of averaged QRS during study, Dynamic ST display (S2). Automatic arrhythmia detection, print and capture VPB and SVPB (S2). Show distance in Km or Miles. Protected against defibrillator shocks. Load, speed, and grade of exercise devices are controlled automatically or via manual control.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Baseline wander, muscle or AC noise, "lead fail", poor 12-lead quality.
Root cause: Poor skin prep, dried or lifting electrodes, or a worn patient cable / lead set.
Symptoms: Acquisition hangs, no interpretation, or a self-test failure.
Root cause: Acquisition-module fault or a software issue.
Symptoms: No or faint report, paper jam, misregistered grid.
Root cause: Thermal print head, paper handling, or (older units) the stylus.
Symptoms: Short battery run time, will not hold charge, will not power on.
Root cause: Aged battery pack.
Symptoms: ECGs will not transmit to the ECG-management system / EMR.
Root cause: Network / Wi-Fi / modem configuration or the communication module.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable / 10-lead set | Frequent wear item | $$ | Easy |
| Acquisition module | Major service part | $$$ | Moderate |
| Thermal print head / paper | Periodic replacement | $ | Fairly easy |
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Communication / modem module | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.