Nihon Kohden · Model MEB-9200A
Neuropack EP/EMG/IOM/EEG Measuring System Nihon Kohden's MEB-9200 are state of the art EP/EMG/IOM instruments with NCS, basic EMG and EP exam software included as a standard feature. The system can be optionally configured with amplifiers from 2, 4, 8 or 16 channels and easily expanded with optional software for a variety of advanced examinations including single fiber and macro EMG, quantitative EMG, ABR and IOM. The Microsoft Windows XP Professional operating system and flexible reporting capability in MS Word or Excel allows for easy review of waveforms, data and information. Features such as the integrated easy touch operation panel and multi tasking windows make the system very user friendly. Nihon Kohden's use of modular USB connectivity allows you to easily add our optional JE-921 32 channel EEG amplifier, photic stimulator and software for a complete multimodality testing system. With these attractive features the Neuropack MEB-9200 system offer the best capability for meeting every lab's testing requirements from single channel nerve conduction studies to 10-20 routine EEG studies. [b][i]This product has been discontinued by the manufacturer.[/i][/b]
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: 50/60 Hz or broadband noise, flat or noisy trace on one or more channels, high electrode impedance.
Root cause: Electrode / lead-wire fault, a headbox / amplifier input fault, or a grounding / environment problem.
Symptoms: No or weak electrical stimulation, no patient response, stimulator-error message.
Root cause: Stimulator probe / bar-electrode fault, its cable, or the stimulator output stage.
Symptoms: One or more channels dead or saturated on all inputs, calibration fails.
Root cause: Headbox / amplifier module fault.
Symptoms: Acquisition hangs, studies will not save or export, license / dongle error.
Root cause: Workstation PC, software, or the license key.
Symptoms: No audio monitor, trigger not registering (evoked potentials).
Root cause: Speaker / audio board or the trigger input.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient lead set / electrode leads | Frequent wear item | $$ | Easy |
| Stimulator probe / bar electrode & cable | Frequent wear item | $$ | Fairly easy |
| Headbox / amplifier module | Major service part | $$$ | Moderate |
| Acquisition PC | Major service part | $$$ | Moderate |
| Audio / speaker board | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.