Nihon Kohden · Model 1550a
Swivel screen - 12.1 inch touch panel TFT LCD with swivel screen lets you change the screen angle to the best viewing position. Same size display image and printout - The screen display and waveforms are the same size as the printout. Also, the display has grid lies just like the recording paper. Large 5 minute memory - The most recent five minutes of all lead ECG waveforms can be stored in memory. This increases the chance to record important data. To save data, you can select, analyze and print just the necessary region from 5 minute full disclosure. Serial comparison - Average waveforms in the latest 5 exams can be compared in the same screen. You can know the changes in time-series basis. Communication capability - Approximately 400 patients x 10 seconds of 12 lead ECG wave and patient information can be stored. Approximately 2,500 patients x 10 seconds of 12 lead ECG wave and patient information can be stored on a QM-040V flash disk card. Stored data can be transferred to PC via QM-040V or LAN/ Wireless LAN interface with optional QB- 903E ECG viewer software.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Baseline wander, muscle or AC noise, "lead fail", poor 12-lead quality.
Root cause: Poor skin prep, dried or lifting electrodes, or a worn patient cable / lead set.
Symptoms: Acquisition hangs, no interpretation, or a self-test failure.
Root cause: Acquisition-module fault or a software issue.
Symptoms: No or faint report, paper jam, misregistered grid.
Root cause: Thermal print head, paper handling, or (older units) the stylus.
Symptoms: Short battery run time, will not hold charge, will not power on.
Root cause: Aged battery pack.
Symptoms: ECGs will not transmit to the ECG-management system / EMR.
Root cause: Network / Wi-Fi / modem configuration or the communication module.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable / 10-lead set | Frequent wear item | $$ | Easy |
| Acquisition module | Major service part | $$$ | Moderate |
| Thermal print head / paper | Periodic replacement | $ | Fairly easy |
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Communication / modem module | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
From BioLab, for work done with this kind of equipment.