Nihon Kohden · Model 1550a
• Swivel screen - 12.1 inch touch panel TFT LCD with swivel screen lets you change the screen angle to the best viewing position. • Same size display image and printout - The screen display and waveforms are the same size as the printout. Also, the display has grid lies just like the recording paper. • Large 5 minute memory - The most recent five minutes of all lead ECG waveforms can be stored in memory. This increases the chance to record important data. To save data, you can select, analyze and print just the necessary region from 5 minute full disclosure. • Serial comparison - Average waveforms in the latest 5 exams can be compared in the same screen. You can know the changes in time-series basis. • Communication capability - Approximately 400 patients x 10 seconds of 12 lead ECG wave and patient information can be stored. Approximately 2,500 patients x 10 seconds of 12 lead ECG wave and patient information can be stored on a QM-040V flash disk card. Stored data can be transferred to PC via QM-040V or LAN/ Wireless LAN interface with optional QB- 903E ECG viewer software.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Flat or noisy ECG, frequent lead-off alarms.
Root cause: Worn electrodes, loose leads, or dry gel.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
| Rechargeable backup battery | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →