NeuroLogica · Model CereTom OTOscan
8 Slice True CT Scanner (NOT flat panel technology). Complete self contained lead shielding. Onboard 10” LCD touch screen. DICOM 3 image sets compatible with all teleradiology services. Integrates with all PACs Desktop Imaging Computer with 20” hi-res LCD Monitor. Hardware. Processor: Intel®Core™ 2 Duo Processor 2.13 GHz. Memory: 2 GB. Hard Drive: 250 GB. OS: Windows XP Professional. Monitor Resolution: 1600 x 1200. Advanced Visualization Software Package (Barco’s Voxar 3D™). 2D. 3D. MPR (Sagittal/Coronal/Transverse) viewing Imaging Station with Integrated Lead Shielding. Clear leaded glass for patient viewing. Swivel casters for easy movement. Cabinet storage for desktop imaging computer. Articulating arm for 20” LCD monitor Direct Coronal/Axial Chair. Ergonomic design provides comfort for all patients (elderly, adults, children). Small footprint. Easily interchangeable adapters allow for coronal & axial scanning 2 Day Onsite Training. Conducted by a NeuroLogica clinical specialist 1 Year All Inclusive Warranty. Covers all parts and labor. Quarterly scheduled onsite preventative maintenance visits. Includes all software updates. OTOscan Move (while under inclusive warranty). FREE transport and set-up within 150 miles (Once per calendar year) Comprehensive Radiation Support Program. Medical physicist services for one year. Assistance in meeting all local & state license requirements.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Ring or band artefacts, excessive noise, HU non-uniformity, failed daily air/water calibration.
Root cause: Detector-channel drift or a bad detector module, a DAS fault, or air-cal / tube-output drift.
Symptoms: Tube-arc errors, exposure aborts, kV/mA faults, spits, or noisy bearing; tube pulls high heat units.
Root cause: Anode / bearing wear or vacuum degradation - the CT tube is a wear item.
Symptoms: Rotation faults, comms errors during rotation, brush dust, drive alarms.
Root cause: Worn slip-ring brushes, a drive-belt / bearing fault, or the data-transmission link.
Symptoms: Table drifts, will not index to the correct position, height or cradle errors.
Root cause: Table drive, encoder, or brake fault.
Symptoms: Recon hangs or is slow, images will not send to PACS, console errors.
Root cause: Recon-hardware or console-PC fault, or the network / storage.
Symptoms: Over-temperature warnings, exposures inhibited after a series, coolant alarm.
Root cause: Chiller pump / fan, low coolant, or a blocked heat exchanger.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Major planned replacement; track heat-unit history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| CT X-ray tube assembly Major planned replacement; track heat-unit history. | Periodic replacement | $$$$ | Expert-level |
| Detector module / DAS board | Major service part | $$$$ | Expert-level |
| Slip-ring brush set | Periodic replacement | $$ | Moderate |
| Gantry drive belt / bearings | Major service part | $$$ | Difficult |
| Table drive / encoder | Major service part | $$$ | Difficult |
| Chiller pump / coolant | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.