NEURALYNX, INC. · Model 384 Channel
The ATLAS Neurophysiology System is intended to be used for temporary (<30 days) recording and monitoring of brain electrical activity. The Pegasus software is a component of the ATLAS Neurophysiology System.
Intended use: An electrically-powered device assembly designed to continuously measure the electrical signals produced by a patient's brain and display/record them as an electroencephalogram (EEG) to evaluate brain function, typically in an examination room or intensive care unit (ICU) [bedside]; it may also monitor additional physiological parameters [e.g., electromyogram (EMG), respiration wave forms, blood pressure, haemoglobin oxygen saturation (SpO2)] in relation to EEG. It typically includes a control unit, electrodes, and components (e.g., amplifier, cables, probes). It may include data interpretation and/or telemetry features.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Noisy / flat channels, impedance alarm.
Root cause: Dry gel, poor contact.
Symptoms: Dead channel, artifact.
Root cause: Front-end amplifier failure.
Symptoms: No stimulus delivered.
Root cause: Stimulator circuit wear.
Symptoms: 50/60 Hz interference.
Root cause: Shield/ground break.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| EEG electrode cap / cup Frequent R&R. | Periodic replacement | $$ | Easy |
| Patient electrode gel Consumable. | Consumable | $ | Easy |
| Amplifier channel module | Periodic replacement | $$$ | Difficult |
| Stimulator cable | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →