MMMind Media Europe B.V. · Model 1.2
The NeXus-10 MKII is designed for medical use, not restricted to a specific medical indication, for acquisition of (electro)-physiological signals (e.g. EEG, EMG or ECG). The product is intended to be used by medical/acces professionals in a laboratory setup or medical office, or to be set-up in such an environment after which the subject/patient can be sent out while signal acquisition continues on memory. The NeXus 10 MKII is not intended for use in diagnosis, nor in critical and/or life supporting applications. The NeXus 10 MKII is intended for use on humans. The NeXus 10 MKII is intended
Intended use: An electronic device that increases current, voltage, or power to adjust the signal level and impedance between two or more medical devices transmitting physiological signals; or the device has the capability of being used for more than a single application, such as electroencephalography (EEG), evoked potential, polysomnography (sleep analysis) and general polygraphy.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Noisy / flat channels, impedance alarm.
Root cause: Dry gel, poor contact.
Symptoms: Dead channel, artifact.
Root cause: Front-end amplifier failure.
Symptoms: No stimulus delivered.
Root cause: Stimulator circuit wear.
Symptoms: 50/60 Hz interference.
Root cause: Shield/ground break.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Amplifier channel module | Periodic replacement | $$$ | Difficult |
| Stimulator cable | Periodic replacement | $$ | Fairly easy |
| EEG electrode cap / cup Frequent R&R. | Periodic replacement | $$ | Easy |
| Patient electrode gel Consumable. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.