Natus · Model Dantec Series
[b]Dantec Keypoint®[/b] The Dantec Keypoint® electromyography (EMG) / evoked potentials (EP) systems are recognized worldwide for their superior amplifiers, stimulators, and outstanding signal quality. The Keypoint is the instrument of choice for advanced neurodiagnostic applications such as Single Fiber EMG, Quantitative EMG, visual and auditory evoked potentials, as well as routine Nerve Conduction studies. The new Keypoint provides ergonomic improvements as well, including a 22 inch articulating monitor, a flexible arm, and a portable control panel. The Keypoint system is also available with all desired applications in a portable laptop configuration. [b]Dantec Clavis™[/b] The Dantec Clavis™ hand-held EMG/STIM device was developed to provide muscle and nerve localization information to assist with botulinum toxin injections. It is perfectly matched for use with Bo-ject® hypodermic needle electrodes.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Noisy / flat channels, impedance alarm.
Root cause: Dry gel, poor contact.
Symptoms: Dead channel, artifact.
Root cause: Front-end amplifier failure.
Symptoms: No stimulus delivered.
Root cause: Stimulator circuit wear.
Symptoms: 50/60 Hz interference.
Root cause: Shield/ground break.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
Frequent R&R.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient electrode gel Consumable. | Consumable | $ | Easy |
| Amplifier channel module | Periodic replacement | $$$ | Difficult |
| Stimulator cable | Periodic replacement | $$ | Fairly easy |
| EEG electrode cap / cup Frequent R&R. | Periodic replacement | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →