Menfis BioMedica · Model Pico Smart
PICO® SMART is based on an advanced acquisition board called ACQ3000 that offers new advanced capabilities. PICO® SMART can either be based on one trolley (all-in-one system) or upon 2 units connected by an Ethernet cable or through a wireless device (option) The pressure channels are compatible both with external transducer for water perfused catheters and solid-state catheters like those manufactured by Unisensor, Gaeltec, Millar and others. The easy accessibility to the channels allows the operator to change the kind of transducers according to the need of the study The uroflowmeter is connected to the acquisition board by means of either a cable 8 m long or a wireless module so that it can be put in a private place to make the patient more comfortable.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Poor cut/coag, sparking, low power.
Root cause: Burned/eroded blade or pencil.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
Symptoms: Dim or dead panel, color shift.
Root cause: LED module aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| OR light LED module | Major service part | $$$ | Difficult |
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.