Laborie Medical · Model Aquarius XT
Powerful Built-in UDS Software. Enjoy uniquely advanced LABORIE features and analysis. Meets the most demanding protocols for all ICS standardized tests. Unique Remote Tower Puts Intuitive Control at Your Fingertips. Wireless touchscreen Central Hub and adaptive Remote Control. Delivers the most natural way of performing Urodynamics for the physician and allows for efficient workflow resulting in shorter test times for patient. Record up to 16 Data Channels. Fully wireless communication. Customize procedures to meet your needs. Seamless i-LIST® Integration. Complete HL7 and EMR connectivity. Performs advanced information analytics. High Specification Industrial PC with Mirrored Hard Drive. Performs complex tasks with speed and efficiency with automatic data backup. Choose 1 or 2 large conventional or touchscreen monitors. Backed by LABORIE's Outstanding Service Program. CME accredited training courses and certified on-site clinical training. Live telephone support and remote dial-in assistance. Multiple Upgrade Options Include. Anorectal Manometry with a 360° ultrasound probe. Video Urodynamics with multi-monitor display to simultaneously monitor bladder and X-Ray images.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Pves / Pabd / Pdet baselines drift, will not zero, subtracted Pdet implausible, calibration fails.
Root cause: Pressure-transducer fault, a leaking / air-bubbled line, or a transducer-dome / stopcock fault.
Symptoms: Flow trace flat, noisy, or implausible, will not calibrate to a known volume.
Root cause: Worn weight-transducer / rotating-disc flowmeter, or debris.
Symptoms: Fill rate inaccurate, pump will not run, infused-volume error.
Root cause: Peristaltic-pump wear or a control fault.
Symptoms: EMG channel noisy or dead, catheter transducer not recognised.
Root cause: EMG lead set, or the amplifier / input board.
Symptoms: Trace drops, amplifier not detected, study will not save or export.
Root cause: USB / link, driver, or the PC / software.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Pressure transducers / domes & tubing | Frequent wear item | $$ | Fairly easy |
| Uroflow transducer | Periodic replacement | $$$ | Moderate |
| Peristaltic infusion pump / tubing | Periodic replacement | $$ | Moderate |
| EMG lead set | Frequent wear item | $ | Easy |
| Amplifier / input board | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.