Medtronic · Model SS-501SX
fully microprocessed 12 cut functions - pure, blend 1, 2 and 3, pure cut with high cut, blend 1, 2 and 3,Ecut 1, 2, 3 and 4 400 W pure cut 2 coagulation modes: contact desiccate and fulgurate spray, which allow for adjusting effects and application areas during tissue coagulation adjustable bipolar mode at 1 W and adjustable microbipolar mode at 0.5 W steps 3 independent digital displays for cut, coagulation and bipolar mode independent footswitches for monopolar 1, monopolar 2 and bipolar controlled by manual pencil and footswitch allows for the use of 2 pencils or 2 monopolar footswitches the PPM system automatically monitors patient-plate contact bargraph indicates contact level with patient plate recall function retrieves saved power levels remote function: controls display power from manual pencil compatible with argon plasma coagulator
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
Symptoms: Slow or drifting positioning.
Root cause: Cylinder seal or actuator wear.
Symptoms: Dim or dead panel, color shift.
Root cause: LED module aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.