Leica Biosystems · Model EG 1160
Precision Paraffin Dispensing Separately Heated Dispenser: Ensures consistent paraffin flow 10 Flow Rate Settings: Adjustable for precise embedding control Integrated Filter System: Maintains clean, reproducible paraffin output Multiple Activation Options: Manual, footswitch, or mold-activated dispensing Advanced Temperature Control Programmable Heating Zones: Paraffin reservoir, cassette bath, mold warmer, and work surface Stable Temperature Regulation: Supports consistent embedding conditions Cold Plate with Refrigeration Spot: Facilitates precise specimen orientation User-Friendly Operation Microprocessor-Controlled System: Easy, one-touch programming Custom Scheduling: Programmable workday, start/end times, and real-time settings Multilingual Interface: Supports German, English, French, Spanish, and Italian Battery-Buffered Memory: Retains settings during power interruptions Ergonomic & Efficient Design Compact Bench-Top Footprint: Ideal for space-limited labs Illuminated Workspace: Enhances visibility during embedding Removable Cassette Bath: Simplifies cleaning and maintenance Heated Forceps Holders: Included on the right, optional on the left Paraffin Level Indicator: Enables efficient workflow management (Generated by AI)
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Stations not filling or draining, retort not filling (processor), transport arm mis-places baskets, error alarm halts the run.
Root cause: Worn pump / valve, a blocked line, a level-sensor fault, or a transport-drive / gripper fault.
Symptoms: Pressure / vacuum not achieved, poor infiltration, seal alarm.
Root cause: Worn retort door seal, a vacuum / pressure-pump fault, or a valve.
Symptoms: Slides over- / under-stained, uneven, station-time drift.
Root cause: Exhausted reagents, wrong programme, incorrect agitation, or a timing / arm fault.
Symptoms: Paraffin not molten or too hot, oven not at temperature, bath alarm.
Root cause: Heater or temperature-sensor fault.
Symptoms: Reagent fumes in the room, filter-change overdue.
Root cause: Saturated carbon filter or a fan fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Reagent / paraffin pump & valves | Periodic replacement | $$$ | Difficult |
| Retort / reagent-vessel seals | Periodic replacement | $$ | Fairly easy |
| Transport-arm drive / gripper (stainer) | Periodic replacement | $$$ | Difficult |
| Bath / oven heater & temperature sensor | Major service part | $$ | Moderate |
| Activated-carbon fume filter | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Extracted directly from this unit's own service manual.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.