Landwind Medical · Model Mirror 2
• PIHI: Pulse Inverse Harmonic Imaging - PIHI is a modality that distort the fundamental pulse signal and extract the pure broadband harmonic signal due to its highest amplitude. Thus PIHI can improve image overall uniformity with high resolution and high penetration than traditional THI (Tissue Harmonic Imaging). • Digital Fine Focusing - The interval of traditional dynamic focusing is more than 0.154mm while digital fine focusing interval is less than 0.02mm. Each sample point can be precisely focused so as to effectively improve the superficial image. • LanSRI: Speckle Reduction Imaging - LanSRI means decompose the image to a group of smaller ones in pyramid structure, analysis the texture information to remove speckle noise in different scales and then reconstruct the image after the noise suppression. LanSRI can help to enhancesmooth along preferred edge direction, reduces variation within speckle region, and maintain local mean gray scale level. • LanBeam: Spatial Compounding Imaging - With LanBeam, the user can scan multiple coplanar images from different angles and combine into a single image in real time, one angle will be perpendicular to round or oval reflector. Doctors can get greater smoothness of borders and interfaces, improved contrast resolution and border detection. • Trapezoidal Imaging - Trapezoidal Imaging Extend the FOV of scanning. Landwind Medicals trapezoidal Imaging is available on convex, linear and endocavity transducers. • Dual Live Display - Dual live displays with grayscale reference image and color Doppler image.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Dropout, dead elements, image banding.
Root cause: Element delamination or cable damage from repeated use.
Symptoms: Intermittent image loss, connector-wiggle artifact.
Root cause: Repeated flexing and connector strain.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Dim image, color shift, dead pixels.
Root cause: Backlight or LCD panel aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Handle with care; most-replaced probe assembly.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Display panel | Major service part | $$ | Moderate |
| Ultrasound transducer / probe Handle with care; most-replaced probe assembly. | Periodic replacement | $$$$ | Moderate |
| Transducer cable assembly | Periodic replacement | $$ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.