Karl Storz · Model Autocon 400 ii
AUTOCON II 400 ESU The is equipped for both bipolar and monopolar output, which enables surgeons to perform resection in either mode. The AUTOCON II 400 ESU offers specially modulated bipolar and monopolar C-Cut modes that result in less bleeding. The result is reproducible coagulation current and high cutting efficiency that reduces the need for subsequent coagulation. The innovative AUTOCON II 400 Electrosurgical Unit (ESU) will offer surgeons a single unit capable of powering both bipolar and monopolar instruments while offering automatic output regulation and optimal hemostasis.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Poor cut/coag, sparking, low power.
Root cause: Burned/eroded blade or pencil.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Residue, bioburden, discoloration.
Root cause: Inadequate cleaning cycle or damaged tray.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover consumable instruments.
Consumable per procedure.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
| Instrument repair / replacement set High-turnover consumable instruments. | Periodic replacement | $$ | Fairly easy |
| Electrosurgical pencil & electrode Consumable per procedure. | Consumable | $ | Easy |
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.