Instrumentation Laboratory · Model 402
Oxygen Monitor, …
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: O2 % biased, drifts, or fails span calibration.
Root cause: Aged galvanic O2 cell or a paramagnetic-sensor fault; or a calibration-gas issue.
Symptoms: Dashes or a sensor-fault message.
Root cause: Depleted O2 cell, a cable fault, or a connector fault.
Symptoms: No or continuous audible alarm, alarm limits will not set.
Root cause: Speaker / audio or the alarm board - a safety function on ventilator O2 monitoring.
Symptoms: Short battery life, will not power on.
Root cause: Aged battery.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Galvanic O2 sensor / cell | Frequent wear item | $$ | Easy |
| Sensor cable | Periodic replacement | $ | Fairly easy |
| Battery | Frequent wear item | $ | Easy |
| Alarm speaker / board | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
This Lot is not meeting labeled on-board instrument stability claims of 5 days.
Some vials of HemosIL PT-Fibrinogen HS PLUS, Part No. 0008469810 (various lots manufactured prior to June 2014) exhibit a yellow/brownish color after reconstitution (yellow color or darker) instead of the typical white to off-white color. Vials exhibiting this yellow/brownish color were observed to cause prolonged prothrombin (PT) clotting times.
Falsely elevated levels may be reported with the HemosIL von Willebrand Factor Activity assay.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio