Somanetics · Model Invos 5100C
Applications for open heart surgery, vascular surgery and ICU intervention. Can be used to measure glomerular perfusion of children. It can be installed directly from the signal baseline rSO2 from all patients before surgery and during surgery. Ability to baseline at both sensors simultaneously or individually reviewed book. Display parameters SQI (Signal Quality Index). There are tables showing support event mark cases capable of causing the irrigation low blood under the tissue (rSO2 down) to the ICU, NICU and for general surgery (OR), vascular surgery (Vascular surgery). Adjust the time scale of the flow chart from 1 to 24 hours rSO2 TFT LCD display screen size 14.1". Print / save data directly via USB. Over 800 reports worldwide (clinical references). More than 6,000 devices were installed. More than 250,000 patients each year. The accuracy is comparable to capture SPECT.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The patient monitoring is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.