Imex Medical Systems · Model ImexLab 9100
Better Patient Care - Test patients over 65, hypertensives, diabetics, smokers and victims of stroke, TIAs or heart attack when PAD symptoms appear and prevent more serious complications or surgeries. Full Range of Modalities - The systems performs a wide range of noninvasive test including arterial pressure studies, bilateral photoplethysmography (PPG) and bilateral pneumoplethysmography for waveform analysis. Disk Storage: - Store test results on disk until you are ready to print. The system generates full-page, color reports in seconds with CPT and ICD-9 codes if desired.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Segmental cuffs will not inflate or hold, pressure leaks off, study will not complete.
Root cause: Worn cuffs / tubing / connectors, an internal pump / valve fault, or a manifold leak.
Symptoms: Flat or noisy PPG / PVR waveform, no Doppler signal.
Root cause: Worn PPG probe or Doppler probe, or a probe-cable fault.
Symptoms: Recorded pressures implausible or biased, calibration fails.
Root cause: Transducer drift or a calibration issue.
Symptoms: Study will not save, calculate ABI, or generate a report.
Root cause: Workstation PC, software, or the interface.
Symptoms: No or faint waveform printout.
Root cause: Printer or paper.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Segmental cuffs & tubing set | Frequent wear item | $$ | Easy |
| PPG / Doppler probe & cable | Periodic replacement | $$ | Fairly easy |
| Internal pump / valve manifold | Major service part | $$ | Moderate |
| Pressure transducer | Major service part | $$ | Moderate |
| Workstation PC / printer | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio