Hitachi Medical Systems · Model Sirius HP/HT 130
• Touch Sensor for Safety - A silent design motor and cushion casters are adopted to stop the system from making a loud noise when travelling. Useful for travel during the night and for shock absorption when going over steps. • Wide Frontal View - The wide frontal view is ensured even if for a short-heighted operator thanks to not only a slim body design but also eliminated high voltage cable in a mono-tank and a low-mounted X-ray tube assembly. • Swiveling Mechanism of the X-ray Tube Assembly - Even when the arm is at a tilt, the body axis of the patient and the axis of the x-ray tube assembly can be matched with this mechanism. This is an indispensable mechanism for fine positioning. • Effective positioning, adjusting the switch - Fine adjustment of the cart positioning is possible using the adjusting switch positioned on the remote panel while carrying out positioning. Contributes to shortening the time necessary for doctor’s rounds.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →