Hitachi Medical Systems · Model Himac CS-GX
Even-quieter operation • Very-low noise design realizes dramatically quieter operation • Operation noise is 46dB (model: CS120GXII), 47dB (CS150GXII) • Disturbing rotor and fan noise is blocked out A compact body with multiple functions • Compact floor standing type • Additional functions to select vacuum status condition Enables you to set up vacuum conditions via a usercustomized display for faster operation • Newly added rotor catalog function • Conveniently shows rotor specifications at a glance The world's greatest RCF • With the high-efficiency vacuum driving unit, acceleration to the maximum rotation speed of 150,000 rpm can be attained in about 100 seconds • No air friction loss operated in a vacuum • Separation time improved 30% over previous models Non-contact imbalance protection • Samples need only be balanced to within 5 mm by eye • When an abnormality occurs in the rotor due to substantial imbalance, rotation is stopped automatically using an advanced non-contact imbalance sensor Safer, self-locking rotor • Simply put the rotor on its spindle and it is locked automatically with centrifugal force • Dual CPU over-speed prevention mechanism
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →