Hitachi Medical Systems · Model DHF-105 CX
C-arm Concealed cable, electromagnetic lock switch, manual braking configuration greatly improved operability. Equipped 6mA high dose rate pulsed fluoroscopy and low exposure amount feature perspective. 5th gear noise clearance and three contrast selection available to more gentle, clear images. Continuous fluoroscopy 30 minutes, and the ball head tube temperature display. Standard with eight image hold feature. Adoption of built-in cables, one-touch electro-magnetic lock, hand brake and wireless footswitch (option) has improved operability 6mA high X-ray dose fluoroscopy function and low exposure dose high image quality pulsed fluoroscopy function are incorporated Max. tube voltage is as high as 110kV, resulting in widened diagnosing area Image adjust function which has preset 3 kinds of Γ curve is built in 30min. continuous fluoroscopy is possible and tube head temperature display is available 8-channel memory function is incorporated as standard
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.