Hitachi Aloka · Model LISENDO 880
HD Analytics™ Advanced HemoDynamic Analytics (HDA) technologies provide a unique and comprehensive evaluation for your patient's cardiovascular health: Vector Flow Mapping (VFM) demonstrates flow dynamics in the heart and vessels in a whole new way. LV eFLOW is a non-invasive imaging feature that lets you see the endocardial border in the left ventricle with higher sensitivity and resolution than ever before. Dual Gate Doppler displays two separate sample gates allowing measurements from two different locations, during the same cardiac cycle. 2DTT Provides precise quantification of strain and strain rate to visualize, quantify and analyze regional and global myocardial mechanics using 2D speckle tracking. Eyeball EF calculates a Biplane EF from automatic traces on both apical 2 and 4 chamber images. eTracking provides multiple parameters necessary for early-stage detection of atherosclerosis. Wave Intensity is a new hemodynamic index that provides information about the dynamic behavior of the heart and the vascular system and their interactions. Premium 3D Imaging The LISENDO 880 offers Bi-Plane Imaging, 3D Zoom, Active 3D, and Wide Angle 3D live imaging to provide a comprehensive set of data for your 3D and 4D Cardiac Evaluation and Analysis... Hitachi Healthcare’s cardiology systems provide: Extraordinary high-resolution digital imaging with single crystal transducers Speckle reduction and edge enhancement technologies providing clearly defined images Broadband harmonics offering significantly enhanced sensitivity and axial resolution Natural Ergonomics design for reduction of muscle loading while scanning
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Dropout, dead elements, image banding.
Root cause: Element delamination or cable damage from repeated use.
Symptoms: Intermittent image loss, connector-wiggle artifact.
Root cause: Repeated flexing and connector strain.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Dim image, color shift, dead pixels.
Root cause: Backlight or LCD panel aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Handle with care; most-replaced probe assembly.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Display panel | Major service part | $$ | Moderate |
| Ultrasound transducer / probe Handle with care; most-replaced probe assembly. | Periodic replacement | $$$$ | Moderate |
| Transducer cable assembly | Periodic replacement | $$ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.