Hitachi Aloka · Model Arietta 60
advanced HemoDynamic Analytics (HDA) technologies provide a unique and comprehensive evaluation for your patient's cardiovascular health: LV eFLOW is a non-invasive imaging feature that lets you see the endocardial border in the left ventricle with higher sensitivity and resolution than ever before. 2DTT Provides precise quantification of strain and strain rate to visualize, quantify and analyze regional and global myocardial mechanics using 2D speckle tracking. eTracking provides multiple parameters necessary for early-stage detection of atherosclerosis. Wave Intensity is a new hemodynamic index that provides information about the dynamic behavior of the heart and the vascular system and their interactions. Hitachi Healthcare’s cardiology systems provide: Extraordinary high-resolution digital imaging with single crystal transducers Speckle reduction and edge enhancement technologies providing clearly defined images User defined and customizable study protocols guaranteeing exam consistency
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
| Network interface card | Major service part | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →